<acronym id="pokdi"><strong id="pokdi"></strong></acronym>
      <acronym id="pokdi"><label id="pokdi"><xmp id="pokdi"></xmp></label></acronym>

      <td id="pokdi"><ruby id="pokdi"></ruby></td>
      <td id="pokdi"><option id="pokdi"></option></td>
      <td id="pokdi"></td>

        1. 教育裝備采購網
          第三屆體育論壇1180*60
          教育裝備展示廳
          www.dongsenyule.com
          教育裝備采購網首頁 > 產品庫 > 產品分類大全 > 儀器儀表 > 專用儀器設備 > 心理/生理及刑偵儀器

          12通道肌電圖(表面/肌肉) 與BNC和SCSI模擬輸出的腦電放大器AnEMG12

          12通道肌電圖(表面/肌肉)  與BNC和SCSI模擬輸出的腦電放大器AnEMG12
          <
          • 12通道肌電圖(表面/肌肉)  與BNC和SCSI模擬輸出的腦電放大器AnEMG12
          >
          產品報價: 面議
          留言咨詢
          加載中
          AnEMG12
          高教
          意大利
          詳細說明

            ? AnEMG12

            12-channel EMG (surface/intramuscular) 

            and EEG amplifier with BNC and SCSI Analog output

            12通道肌電圖(表面/肌肉)

            與BNC和SCSI模擬輸出的腦電放大器12通道肌電圖(表面/肌肉)  與BNC和SCSI模擬輸出的腦電放大器AnEMG12

            General Description: AnEMG12 is a multichannel analog amplifier for bioelectrical signals surface electromyographic signals (sEMG),  intramuscular electromyographic signals (iEMG), electroencephalographic signals (EEG) and electrocardiographic signals (ECG). The AnEMG12 can amplify 12 bioelectrical signals in two modalities monopolar and differential. Selectable gain can be modified for each inputs. AnEMG12 instrument is completely safe for the patient. The safety is achieved by means of medical grade electrical insulation of all the circuitry connected to the patient.The signals acquired by the instrument are amplified, filtered, digitally converted optocoupled and than analogue converted and then available at BNC or SCSI Analog Output connectors. 

            Deatails:  AnEMG12 allow acquiring, in any configuration, 4 additional signals on the auxiliary inputs (AUX-INPUTS). The signals can be generated by other amplifiers (e.g. force, torque, angle, position or trigger signals) that do not need an optical insulation.

            Developped with: Ernest N. Kamavuako, Head of Laboratory for Invasive Myoelectric Control, Department of Health Science and Technology, Aalborg University, Denmark

            12通道肌電圖(表面/肌肉)  與BNC和SCSI模擬輸出的腦電放大器AnEMG12?

          留言咨詢
          姓名
          電話
          單位
          信箱
          留言內容
          提交留言
          聯系我時,請說明是在教育裝備采購網上看到的,謝謝!
          同類產品推薦
          99久久国产自偷自偷免费一区|91久久精品无码一区|国语自产精品视频在线区|伊人久久大香线蕉av综合

            <acronym id="pokdi"><strong id="pokdi"></strong></acronym>
              <acronym id="pokdi"><label id="pokdi"><xmp id="pokdi"></xmp></label></acronym>

              <td id="pokdi"><ruby id="pokdi"></ruby></td>
              <td id="pokdi"><option id="pokdi"></option></td>
              <td id="pokdi"></td>