<acronym id="pokdi"><strong id="pokdi"></strong></acronym>
      <acronym id="pokdi"><label id="pokdi"><xmp id="pokdi"></xmp></label></acronym>

      <td id="pokdi"><ruby id="pokdi"></ruby></td>
      <td id="pokdi"><option id="pokdi"></option></td>
      <td id="pokdi"></td>

        1. 教育裝備采購網
          第三屆體育論壇1180*60
          教育裝備展示廳
          www.dongsenyule.com
          教育裝備采購網首頁 > 產品庫 > 產品分類大全 > 實驗室設備 > 衛生醫療器械

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體
          <
          • RSD RS-250頭部CT模體,RS-250頭部彷真CT模體
          >
          產品報價: 100000
          留言咨詢
          加載中
          美國RSD
          RSD RS-250
          高教
          上海
          詳細說明

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          型號:RS-250 類別: 質控模體 品牌:美國RSD pdf資料: RSD RS-250頭部CT模體,RS-250頭部彷真CT模體.pdf
          RSD RS-250 頭部CT模體,RS-250頭部彷真CT模體特點:
          擬人化
          被鑄造的Acround頭骨
          檢查重要的物理參數
          提供真實的系統檢查
          理想的培訓
          聚碳酸酯底座的尺寸適用于與縱軸平行或垂直的掃描

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          A部分: 0.4毫米厚的鋁板設置45°角,測量光束寬度和切片厚度。
          RS-250 A部分

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          B部分:劑量測定部分提供患者暴露控制,并在實際患者掃描前檢查異常內部劑量。定制容納TLD與棒或芯片是可用的。
          RS-250 B部分
          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          C部分:分級大小和放射性的圓柱形腫瘤建立高對比度和低對比度分辨率,并顯示部分光束平均效應。
          RS-250 C部分
          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          D部分:擬人部分在空氣對比的內耳和骨折的巖骨中提供實際的聽覺小骨。后顱窩小腫瘤被放置在大多數掃描儀難以成像的區域。

          RS-250 D部分
          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          E部分:人體模型縱軸上1/4英寸直徑的鋁棒,檢查一般對準情況,“干水”給出了一個現實的“噪音檢查”。

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          CT Head with 5 slices to test all parameters of computerized tomography
          Anthropomorphic
          Molded Around Skull
          Checks Important Physical Parameters
          Provides Realistic System Check
          Ideal For Training
          Polycarbonate Base Dimensioned For Scans Parallel or Perpendicular to Longitudinal Axis
          SECTION A: Aluminum plates, 0.4mm thick, set at a 45° angle, measure beam width and slice thickness.

          SECTION B: The dosimetry section provides patient-exposure controls, and checks on abnormal internal doses before actual patient scans. Customization to accommodate TLD with rods or chips is available.

          SECTION C: Cylindrical tumors of graded sizes and radiodensities establish high and low-contrast resolution and demonstrate partial beam-averaging effects.

          SECTION D: The anthropomorphic section provides actual auditory ossicles in an air-contrast inner ear and a fractured petrous bone. Small tumors in the posterior fossa are placed in an area which most scanners image with difficulty.

          SECTION E: 1/4 Inch diameter aluminum rod on the phantom's longitudinal axis, checks general alignment, and "DryWater" gives a realistic "noise check."
          SAG: RS-250,RSD RS-250,RS-250頭部CT模體,頭部CT模體,RS-250 CT模體

          RSD RS-250頭部CT模體,RS-250頭部彷真CT模體

          留言咨詢
          姓名
          電話
          單位
          信箱
          留言內容
          提交留言
          聯系我時,請說明是在教育裝備采購網上看到的,謝謝!
          同類產品推薦
          99久久国产自偷自偷免费一区|91久久精品无码一区|国语自产精品视频在线区|伊人久久大香线蕉av综合

            <acronym id="pokdi"><strong id="pokdi"></strong></acronym>
              <acronym id="pokdi"><label id="pokdi"><xmp id="pokdi"></xmp></label></acronym>

              <td id="pokdi"><ruby id="pokdi"></ruby></td>
              <td id="pokdi"><option id="pokdi"></option></td>
              <td id="pokdi"></td>